• Infitek Double Beam UV-Visible Spectrophotometer with CE FDA
  • Infitek Double Beam UV-Visible Spectrophotometer with CE FDA

Infitek Double Beam UV-Visible Spectrophotometer with CE FDA

After-sales Service: Free Spare Parts; Online Support
Application: Laboratory Apparatus
Warranty: > 1Year
Detection Method: Spectrophotometer
Advantage: High Resolution
Principle: New Spectrometer
Customization:
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Shandong, China
to see all verified strength labels (20)
  • Overview
  • Features
  • Specifications
  • Packging and Shipping
  • Certificates
  • About us
  • FAQ
Overview

Basic Info.

Model NO.
SP-LUV1910/SP-LUV1920
Wavelengths
UV Spectrometer
Certification
ISO9001, CE, FDA
Transport Package
High-Quality Cartons/Crates
Trademark
Infitek
Origin
China
Production Capacity
200 Units/Month

Product Description

Infitek Double Beam UV-Visible Spectrophotometer with CE FDA
Infitek Double Beam UV-Visible Spectrophotometer with High resolution High stability
Features

Features
1.Spectral bandwidth: The spectral bandwidth of the instrument is 1nm / 2nm, which ensures excellent spectral resolution and accuracy required for analysis.
2.Ultra-low stray light: excellent C-T monochromator optical system, advanced electronic system, to ensure ultra-low stray light level better than 0.03%, to meet the user's measurement needs of high absorbance samples.
3.High-quality devices: The core devices are made of high-quality imported parts to ensure the stability and longevity of the instrument. For example, the core light source device is derived from the long-life deuterium lamp of Hamamatsu in Japan, which guarantees a working life of more than 2000 hours, greatly reducing the maintenance frequency and cost of daily replacement of the light source of the instrument.
4.Long-term stability and reliability: The design of the optical dual-beam optical system, coupled with real-time digital proportional feedback signal processing, effectively offsets the signal drift of light sources and other devices, ensuring the long-term stability of the instrument baseline.
5.High wavelength accuracy: The high-level wavelength scanning mechanical system ensures the accuracy of wavelengths better than 0.3nm and the repeatability of wavelengths better than 0.1nm. The instrument uses the built-in spectral characteristic wavelengths to automatically perform wavelength detection and correction to ensure long-term wavelength accuracy stability.
6.Light source replacement is convenient: the instrument can be replaced without removing the shell. The light source switching mirror supports the function of automatically finding the best position. The in-line deuterium tungsten lamp design does not require optical debugging when replacing the light source.
7.Instrument is rich in functions: The instrument is equipped with a 7-inch large-screen color touch LCD screen, which can perform wavelength scanning, time scanning, multi-wavelength analysis, quantitative analysis, etc., and supports the storage of methods and data files. View and print the map. Easy to use, flexible and efficient.
Powerful PC software: the instrument is connected to the computer via USB. The online software supports multiple functions such as wavelength scanning, time scanning, kinetic testing, quantitative analysis, multi-wavelength analysis, DNA / RNA analysis, instrument calibration, and performance verification. Support user authority management, operation traceability, and meet various requirements in different analysis fields such as pharmaceutical companies.

Specifications
Model SP-LUV1910/SP-LUV1920
Optical system Optical double beam system
Monochromator system Czerny-Turner monochromator
Grating 1200 lines / mm high-quality holographic grating
Wavelength range 190nm~1100nm
Spectral bandwidth 1nm(SP-LUV1910) / 2nm(SP-LUV1920)
Wavelength accuracy ±0.3nm
Wavelength reproducibility ≤0.1nm
Photometric accuracy ±0.002Abs(0~0.5Abs),±0.004Abs(0.5~1.0Abs),±0.3%T(0~100%T)
Photometric reproducibility ≤0.001Abs(0~0.5Abs),≤0.002Abs(0.5~1.0Abs),≤0.1%T(0~100%T)
Stray light ≤0.03%(220nm,NaI;360nm,NaNO2)
Noise ≤0.1%T(100%T),≤0.05%T(0%T) ,≤±0.0005A/h(500nm,0Abs,2nm bandwidth)
Baseline flatness ±0.0008A
Baseline noise ±0.1%T
Baseline stability ≤0.0005Abs/h
Modes T/A/Energy
Data range -0.00~200.0(%T)   -4.0~4.0(A)
Scan speed High / medium / low / very low
WL scan interval 0.05/0.1/0.2/0.5/1/2 nm
Light source Japan Hamamatsu long-life deuterium lamp, imported long-life halogen tungsten lamp
Detector Photocell
Display 7-inch large-screen color touch LCD screen
Interface USB-A/USB-B
Power AC90V~250V,  50H/ 60Hz
Dimension 600×470×220mm
Weight 18Kg
Packging and Shipping

 

Infitek Double Beam UV-Visible Spectrophotometer with CE FDA
Certificates

 

Infitek Double Beam UV-Visible Spectrophotometer with CE FDA
About us

Infitek Double Beam UV-Visible Spectrophotometer with CE FDA

Infitek Double Beam UV-Visible Spectrophotometer with CE FDA
FAQ

Q: How about quality of the goods?

A:lAll the running products comply with CE standards.

lIndependent quality inspection team, conducting multiple inspections and random inspections from parts supply to product dispatch.

lWell-known third-party testing service available, such as SGS, BV, and TUV, etc.

Q: What are your pre- and after-sales services?

A:lTimely reply to pre-sales enquiries

lReal-time update of manufacturing and shipment status

lContracted third-party maintenance company in over 60 countries

   lAssured availability of parts supply for 10 years at least

Q: Is OEM service available.

A: Most of the running products are available for OEM customization, including logo, package and function, if attainable, customization.

Q: How long is the lead time:

A: Generally, the lead time for most stocked products is about 7~15 days, vary by models and production schedule. For those non-stocked products, the manufacturing lead time is around 20 days.
Infitek Double Beam UV-Visible Spectrophotometer with CE FDA

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now